Abstract:In order to solve the problem that the voltage amplitude of the unsecured power signal cannot be accurately identified in
the process of ESAD unsecured power signal, an optimization method for the unsecured power signal identification in ESAD is pro-
posed. The method adopts the "digital + analog" recognition methods, using optical coupling isolation circuit as a way to identify
digital quantity, AD sampling circuit as a way to identify analog quantity, "digital + analog" signal as the arming condition. By using
analog recognition value as the threshold of initial judgment and digital signal to judge effectively, the reliability of ESAD function
can be improved. The verification test shows that the identification method of "digital + analog" can effectively identify the signal
and ensure the reliability of ESAD.
孙国先 赵永昌. ESAD中解保电源信号识别优化方法[J]. 电脑与电信, .
SUN Guo-xian ZHAO Yong-chang. An Optimization Method forArming Power Signal Identification in ESAD. Computer & Telecommunication, 2020, 1(7): 58-61.